WARNING: Flush sanitizing solution from the syrup systems as instructed. Residual sanitizing solution left in the syrup systems could create a health hazard.
18.Fill syrup tank (syrup tank system) or a
19.Syrup Tank Systems.
Connect syrup tank containing potable water, pressurized at 60 to
Place all
20.Flush sanitizing solution from the syrup system and the dispensing valve as follows:
A.Place waste container under applicable dispensing valve.
B.Activate the dispensing valve for one minute to purge all sanitizing solution out of the syrup system and the dispensing valve.
C.Continue to activate the dispensing valve in cycles (“ON”for
21.Repeat steps NO TAG and NO TAG preceding to purge sanitizing solution out of the remaining syrup systems and
dispensing valves.
22.Remove potable water source from the syrup system.
STEP 5. PURGE WATER OUT OF SYRUP SYSTEMS (RESTORE OPERATION)
23.Syrup Tank Systems.
A.Noting syrup tanks CO2 regulator pressure setting observed in step 4 preceding, readjust CO2 regulator to the observed pressure setting,
B.Connect tanks containing syrup into syrup systems.
C.Remove all bag valves from
D.Connect
24.Place waste container under dispensing valves. Dispense from all dispensing valves to permit syrup to purge all potable water from the syrup systems and the dispensing valves. Continue to dispense from the dispensing valves until only syrup is dispensed from the syrup systems and valves.
WARNING: To avoid possible personal injury or property damage, do not attempt to remove the syrup tank cover until CO2 pressure has been released from the tank.
25.Dispose of waste sanitizing solution in a sanitary sewer, not in a storm drain, then thoroughly rinse the inside and the outside of the container that was used for sanitizing solution to remove all sanitizing solution residue.
25 | 300614000 |