5300614000
INSTALLATION
This section coversunpacking and inspection,selecting location,installing the Cooling Unitand the Remote
CondenserCoil and Fan Assemblypreparing foroperation,and operation.

UNPACKINGAND INSPECTION

NOTE:TheCooling Unitand theRemoteCondenserCoil and FanAssemblywerethoroughlyinspected
beforeleaving thefactory and the carrierhas acceptedand signedforthem.Anydamageor
irregularities should benotedat timeofdelivery(ornotlaterthan15 days fromdateofdelivery)and
immediatelyreportedtothedelivering carrier.Requestawritteninspection report fromClaims
Inspectortosubstantiate anynecessary claim.File claimwiththedelivering carrier,notwithIMI
CorneliusInc.
1.AfterCooling Unithasbeen unpacked,removeshipping tape and otherpacking material.
2.Unpack LOOSE-SHIPPEDPARTS.Makesureall itemsare presentand in good condition.
Table 2.Loose-ShippedParts
Item
No.PartNo.NameQty.
1 309852000 Tubing Clamp 24
2 770407 Barbed Connector,1/4 by3/8 12
3 770424 Barbed Connector,1/2 by1/2 2
4 311962000 Label,Line Identification 1
NOTE:Thefollowing RemoteCondenserCoil and FanAssembly and Refrigeration LineKits arerec-
ommendedforuse withCooling Unit (P/N416654000).Refrigeration Lines Kit (as ordered)isusedto
connectCondenserCoil and FanAssemblytotheCooling Unit.
5 309602000 RemoteCondenserCoil and Fan Assy1
6 300598025 Refrigeration Line Kit, 25-ft. long,90 1
300598050 Refrigeration Line Kit, 50-ft. long,90 1

IDENTIFICATIONOF LOOSE-SHIPPEDPARTS

1.BARBED CONNECTORS(item2)used toconnectCooling Unitoutletlinestoinsulated python lines.
Connectionsaresecured withTUBINGCLAMPS (item1).
2.BARBED CONNECTORS(item3)are used toconnectCooling Unitoutletcarbonated waterlinesto
insulated python lines.
3.LABEL,LINEIDENTIFICATION(item4)tobeinstalledon Cooling Unitand syrup flavorstoberecordedin
properspaceson label.
4.REFRIGERATIONLINE KIT(items6)isused toconnectREMOTECONDENSER COILAND FANASSY
(item5)toCooling Unit.

SELECTINGLOCATION

COOLINGUNIT

Selectlocation forCooling Unitinstallation thatwill (1)Allowthe shortestpossibleinsulated python routefrom
the Cooling Unit tothe Dispensing Station location;(2)Allowthe shortestpossiblerefrigeration lines(not to
exceed 50-ft inlength) routefromRemoteCondenserCoil and Fan Assemblytothe Cooling Unit; (3)REFER
TOTHECOOLINGUNITNAMEPLATEFORTHEREQUIREDPOWERCIRCUITOPERATINGVOLTAGE,HZ,
AND THEMINIMUMCIRCUITAMPACITYOF THECOOLINGUNIT.The powercircuitforthe Cooling Unit
mustbe wired through a 40-ampminimumrated disconnectswitch(notprovided)and the powercircuitmustbe