OPERATORS INSTRUCTIONS

This section covers operating controls, daily pre-operation check, adjustments, replenishing CO2 and syrup supplies, cleaning and sanitizing, Cooling Unit maintenance, Remote Condenser Coil and Fan Assembly maintenance, lubrication, and servicing CO2 gas check valves.

WARNING: Disconnect electrical power to Cooling Unit and Remote Condenser Coil and Fan Assembly to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service internal components or electrical wiring.

OPERATING CONTROLS

COOLING UNIT REFRIGERATION POWER SWITCH

(see Figure 5)

REFRIGERATION POWER switch, located on front of Cooling Unit, placed in ‘OFF’position will interrupt electrical power to refrigeration compressor, agitator motor, compressor cooling fan, carbonated water circulating pump, and the carbonator pump motor. REFRIGERATION POWER switch placed in ‘ON’position will start the carbonator pump motor (if carbonated water is being called for), the carbonated water circulating pump motor, and the agitator motor. Under certain conditions approximately 2-1/2 minutes after the REFRIGERATION POWER SWITCH has been placed in ‘ON’position refrigeration compressor and compressor cooling fan will start.

COOLING UNIT CARBONATOR MOTOR SWITCH

(see Figure 5)

CARBONATOR MOTOR power switch, located on front of Cooling Unit, placed in ‘OFF’position will interrupt electrical power to carbonator pump motor. Switch must be placed in ‘ON’position before carbonator pump motor will operate.

COOLING UNIT CIRCULATING MOTOR SWITCH

(see Figure 5)

CIRCULATING MOTOR power switch, located on front of Cooling Unit, placed in ‘OFF’position will interrupt electrical power to carbonated water circulating pump. Switch must be placed in ‘ON’position before circulating pump will operate.

REFRIGERATION SYSTEM TEMPERATURE SENSING DEVICE AND HIGH-PRESSURE CUTOUT SWITCH

(see Figure 5)

This Cooling Unit is equipped with a refrigeration system temperature sensing device and a high-pressure sensing cutout switch that will shut refrigeration system down should the system overheat due to a clogged condenser coil in the Remote Condenser Coil and Fan Assembly. If refrigeration system does not automatically restart itself after system has cooled down, high-pressure sensing cutout switch (see Figure 5) will have to be pressed to reset switch. MAKE SURE REFRIGERATION SYSTEM PROBLEM IS CORRECTED. OPERATING REFRIGERATION SYSTEM IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD RESULT IN COMPRESSOR FAILURE.

13

300614000

Page 17
Image 17
Cornelius 000 PLUS, 10 Operating Controls, Cooling Unit Refrigeration Power Switch, Cooling Unit Carbonator Motor Switch

000 PLUS, 10 specifications

Cornelius 10,000 PLUS is a pioneering innovation in the beverage dispensing industry, designed to cater to the evolving needs of commercial establishments. This advanced system combines state-of-the-art technology with user-friendly features, making it a standout choice for restaurants, cafes, and bars aiming to enhance their beverage service.

One of the main features of the Cornelius 10,000 PLUS is its impressive capacity. With the ability to dispense a wide variety of beverages, including soft drinks, cocktails, and craft beers, the system supports a large volume of service, perfect for high-demand environments. The modular design allows for easy expansion, enabling businesses to add additional flavors or beverages as needed without major overhauls.

The technology behind the Cornelius 10,000 PLUS is equally impressive. It utilizes advanced cooling technology to ensure that beverages are served at the optimal temperature, enhancing the customer experience. The integrated touchless dispensing mechanism minimizes waste and ensures a hygienic experience, addressing growing concerns about cleanliness in food service environments. This technology also improves speed, allowing staff to serve customers more efficiently.

Another key characteristic of the Cornelius 10,000 PLUS is its digital integration capabilities. The system can be connected to a central management platform that tracks sales, inventory levels, and maintenance needs in real-time. This allows operators to optimize their beverage offerings based on customer preferences and reduces downtime through proactive maintenance alerts.

In addition to its performance features, the Cornelius 10,000 PLUS is designed with sustainability in mind. The system employs energy-efficient practices, reducing its environmental footprint while lowering operational costs. The materials used in construction are durable yet eco-friendly, ensuring longevity and less waste.

Overall, the Cornelius 10,000 PLUS stands out as an essential tool for any business looking to elevate its beverage service. With its combination of high capacity, cutting-edge technology, and sustainability features, it not only meets the demands of today’s fast-paced service environments but also positions establishments for future growth and success.