CHANGING VOLTAGE
See Figures 2-4.
Your radial saw has been set upat the factory to
operate efficiently on a 120V AC single voltage circuit.
However, if heavy duty operation is required,the
circuits are overloaded, or the circuit is low voltage,
have a qualified electrician change the voltage on the
main power system to a 240V AC voltage circuit.
AWARNING: The controlcut deviceis set up for
a 120V AC single voltage circuit, Do not modify
the control cut cord. identifythe control cut
cord and tie itback out of the way.
Correctly identify the control cut cord, unplug it,
and set it aside.
Unplug the main power cord.
Remove the blade following the procedure inthe
Assembly section.
Remove the pan head screw above the blade
arbor on the motor cover. Liftmotor cover to
expose switch. See Figure 2.
Use a small screwdriver to slide the dual voltage
switchto the 240V position. See Figures 3 and 4.
Reinstallmotor cover.
Replace the 120V plug on the main cord with aUL
listed240V, 15 amp, 3-prong plug.
Followthe instructions providedwith the UL listed
plug.
Plug the cord into a240V, 15 amp, 3-blade recep-
tacle. Make sure the receptacle isconnected to a
240V AC power supply through a 240V branch
circuitthat has a 15 amp fuse orcircuit breaker.
Note: No adapter is available for thistype of plug or
receptacle.
PANHEADSCREW
MOTORCOVER
UFT MOTORCOVERTOEXPOSESWITCH
SLIDEASSHOWNFORSINGLEVOLTAGECIRCUITS
SWITCHSHOWNIN110-120VOLTPOSITION Fig. 3
LIFTMOTORCOVERTOEXPOSESWITCH
SLIDEASSHOWNFORDUALVOLTAGECIRCUITS
SWITCHSHOWNIN220-240VOLTPOSITION Fig.4
BLADEARBOR Fig. 2 9 [RRFTSMRN"RADIALSAW315.220380