Configure the Sensor Configuration Parameters

2. On the Sensor Configuration page, enter values for the parameters indicated in Table 2-13.

Table 2-13. Sensor Configuration Parameters

Web Page Item

Description

 

 

Door Sensor Settings

 

 

 

Door Sensor Normally Closed

Select the inactive state of the door sensors.

 

 

Door Open Timeout (in seconds)

Select the number of seconds that you want to pass before the

 

door sensor is activated.

 

 

Flash Button LED

Check this box to flash the LED until the sensor is deactivated

 

(roughly 10 times/second).

 

 

Activate Relay

Check this box to activate the relay until the sensor is deactivated.

 

 

Play Audio Locally

Check this box to loop an audio file out of the Intercom speaker

 

until the sensor is deactivated.

 

 

Make call to extension

Check this box to call a preset extension (once).

 

 

Play recorded audio

Check this box to play a pre-recorded audio file (once).

 

 

Dial Out Extension

Enter the desired dial-out extension number.

 

 

Dial Out ID

Type the desired Extension ID (64 character limit).

 

 

 

Use this button to test the door sensor.

 

 

Intrusion Sensor Settings

 

 

 

Flash Button LED*

Check this box to flash the LED until the sensor is deactivated

 

(roughly 10 times/second).

 

 

Activate Relay

Check this box to activate the relay until the sensor is deactivated.

 

 

Play Audio Locally

Check this box to loop an audio file out of the Intercom speaker

 

until the sensor is deactivated.

 

 

Make call to extension

Check this box to call a preset extension (once).

 

 

Play recorded audio

Check this box to play a pre-recorded audio file (once).

 

 

Dial Out Extension

Enter the desired dial-out extension number.

 

 

Dial Out ID

Type the desired Extension ID (64 character limit).

 

 

 

Use this button to test the Intrusion sensor.

 

 

 

Click the Save button to save your configuration settings.

 

Note: You need to reboot for changes to take effect.

 

 

 

Click on the Reboot button to reboot the system.

3. After changing the parameters, click Save Settings.