CY7C1360C
CY7C1362C
Document #: 38-05540 Rev. *H Page 24 of 31
ZZ Mode Timing[27, 28]
Notes:
27.Device must be deselected when entering ZZ mode. See Cycle Descriptions table for all possible signal conditions to deselect the device.
28.DQs are in High-Z when exiting ZZ sleep mode.
Switching Waveforms (continued)
tZZ
I
SUPPLY
CLK
ZZ
tZZREC
A
LL INPUTS
(except ZZ)
DON’T CARE
IDDZZ
tZZI
tRZZI
Outputs (Q)
High-Z
DESELECT or READ Only
[+] Feedback