Battery
System battery | CR 2477N 3.0 V Lithium coin cell |
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Expanded operating temperature
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event Log.
≤ 10% of annual operating hours | 5 °C to 10 °C (41 °F to 50 °F), and 35 °C to 40 °C (95 °F to |
| 104 °F) at 5% to 85% RH with 29 °C (84.2 °F) dew point. |
| NOTE: Outside the standard operating temperature |
| (10 °C to 35 °C), the system can operate down to 5 |
| °C or up to 40 °C for a maximum of 10% of its annual |
| operating hours. |
| For temperatures between 35 °C and 40 °C, |
| maximum allowable dry bulb temperature by 1 °C per 175 |
| m above 950 m (1 °F per 319 ft). |
≤ 1% of annual operating hours | |
| 113 °F) at 5% to 90% RH with 29 °C (84.2 °F) dew point. |
Expanded operating temperature restrictions
Temperature
Maximum Temperature Gradient (Operating and Storage)
Storage Temperature Limits
Temperature (Continuous Operation)
Temperature Ranges (for altitude less than 950 m or 3117 ft)
Humidity Percentage Range
Relative Humidity
NOTE: Outside the standard operating temperature (10 °C to 35 °C), the system can operate down to
For temperatures between 40 °C and 45 °C,
Do not perform a cold startup below 5 °C.
20 °C/h (36 °F/h)
10 °C to 40 °C (50 °F to 104 °F) with no direct sunlight on the equipment.
10% to 80% Relative Humidity with 29 °C (84.2 °F) maximum dew point.
66