to Managed Mode. The chapter "Starting and Configuring the Dell™PowerConnect™ 2708/2716/2724/2748 for Managed Mode Operation" explains how to set the switch to Managed Mode.
Site Requirements
The PowerConnect 2708/2716/2724/2748 devices can be mounted in a standard equipment rack, placed on a tabletop, or mounted on the wall.
Before installing the unit, verify that the site selected for the device meets the following site requirements:
•Power — The device is installed within 1.5 m (5 feet) of a grounded, easily accessible outlet 220/110 VAC, 50/60 Hz. If the device has two power supplies, the site should have two power outlets with different power feeders.
•General — Ensure that the power supply is correctly installed.
•Clearance — There is adequate frontal clearance for operator access. Allow clearance for cabling, power connections, and ventilation.
•Cabling — Cabling is routed to avoid sources of electrical noise such as radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting fixtures.
•Ambient Requirements — The ambient unit operating temperature range is 0 to 45C (32 to 113F) at a relative humidity of up to 95%,
Unpacking
NOTE: Before unpacking the device, inspect the packaging and report any evidence of damage immediately to Dell.
Safety
CAUTION: Never remove the cover on a power supply or any part that has the following label attached.
Figure
CAUTION: Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician.