Message

Causes

Corrective Actions

PCIe Training Error: Expected Link Width is x, Actual Link Width is y.

Faulty or improperly installed PCIe card in the specified slot.

Reseat the PCIe card in the specified slot number. See "Troubleshooting an Expansion Card" on

page 109. If the problem persists, see "Getting Help" on page 119.

SATA Portx

There is no device connected

Information only.

device not

to the specified SATA port.

 

found.

 

 

SATA port x

The drive connected to the

Replace the faulty drive.

device auto-

specified SATA port is faulty.

 

sensing error.

 

 

SATA port x

 

 

device

 

 

configuration

 

 

error.

 

 

SATA port x

 

 

device error.

 

 

The amount of

Memory has been added or

If memory has been added or

system memory

removed or a memory

removed, this message is

has changed.

module may be faulty.

informative and can be

 

 

ignored. If memory has not

 

 

been added or removed,

 

 

check the SEL to determine

 

 

if single-bit or multi-bit

 

 

errors were detected and

 

 

replace the faulty memory

 

 

module. See

 

 

"Troubleshooting System

 

 

Memory" on page 104.

 

 

 

Time-of-day not

Incorrect Time or Date

Check the Time and Date

set - please run

settings; faulty system

settings. See "Using the

SETUP program.

battery.

System Setup Program and

 

 

Boot Manager" on page 25. If

 

 

the problem persists, replace

 

 

the system battery. See

 

 

"System Battery" on page 89.

About Your System

21

Page 21
Image 21
Dell R210 II owner manual There is no device connected Information only