Chapter 39 Compare API | PCI-DMC-A01 / PCI-DMC-B01
39-12 Revised March, 2012
Custom mode
When set to custom mode, level table's value is set to 0x88880000 as shown in Fig. 39.2.
Figure 39.2 Compare Output's custom mode
In custom mode, Trigger On's position table is set
using the “level_table” parameter in
API”_DMC_01_channel1_position_compare_table_level”.
Trigger time is the time required to reach the next position (ex. time taken to move from
position 1000 to position 2000)
Example
U16 CardNo = 0;
U16 Mode = 1;