In order to properly setup the digital outputs an initialization PLC must be written scanning through once on power-up/reset, then disabling itself:

OPEN PLC1 CLEAR

;BITS 0-8 are assigned as output

M32=$FF

M34=$0

;BITS 9-16 are assigned as input

M40=$FF00

;Define inputs and outputs voltages

M42=$FFFF

;All lines are I/O type

DIS PLC1

;Disable PLC1 (scanning through once on

CLOSE

;power-up/reset)

 

 

 

 

 

 

Note:

After loading this program, set I5=2 or 3 and ENABLE PLC 1.

Acc-2P with Jumper E5 in Position 2-3

M0->Y:$C0C0,0

; Digital Output M00

 

M1->Y:$C0C0,1

; Digital Output M01

 

M2->Y:$C0C0,2

; Digital Output M02

 

M3->Y:$C0C0,3

; Digital Output M03

 

M4->Y:$C0C0,4

; Digital Output M04

 

M5->Y:$C0C0,5

; Digital Output M05

 

M6->Y:$C0C0,6

; Digital Output M06

 

M7->Y:$C0C0,7

; Digital Output M07

 

M8->Y:$C0C0,8

; Digital Input MI0

 

M9->Y:$C0C0,9

; Digital Input MI1

 

M10->Y:$C0C0,10

; Digital Input MI2

 

M11->Y:$C0C0,11

; Digital Input MI3

 

M12->Y:$C0C0,12

; Digital Input MI4

 

M13->Y:$C0C0,13

; Digital Input MI5

 

M14->Y:$C0C0,14

; Digital Input MI6

 

M15->Y:$C0C0,15

; Digital Input MI7

0 = input)

M32->X:$C0C0,0,8

; Direction Control (1=output,

M34->X:$C0C0,8,8

; Direction Control (1=output,

0 = input)

M40->X:$C0C4,0,24

; Inversion control (0 = 0V, 1 = 5V)

M42->Y:$C0C4,0,24

; JI/O port data type control (1 = I/O)

In order to properly setup the digital outputs, an initialization PLC must be written scanning through once on power-up/reset, and then disabling itself:

OPEN PLC1 CLEAR

;BITS 0-8 are assigned as output

M32=$FF

M34=$0

;BITS 9-16 are assigned as input

M40=$FFFF

;Define inputs and outputs voltages

M42=$FFFF

;All lines are I/O type

DIS PLC1

;Disable PLC1 (scanning through once on

CLOSE

;power-up/reset)

 

 

 

 

 

 

Note:

After loading this program, set I5=2 or 3 and ENABLE PLC 1.

26

Software Setup

Page 32
Image 32
Delta Tau PMAC2A-PC/104 manual Acc-2P with Jumper E5 in Position, Open PLC1 Clear