2.3 RELAY WIRING (TYPICAL)

2.3 RELAY WIRING (TYPICAL)

2.3.1 Controlling a Single Door or Gate

Relay 1 is typically used when the system will control a single door or vehicular gate operator. Note that the electric strike and magnetic lock are each powered by their own power supply. Electric strikes are connected through the normally open (NO) contact and magnetic locks are connected through the normally closed (NC) contact.

Relay 0 COM

Relay 0 NC

Relay 0 NO

Relay 0

Relay 2 COM

Relay 2

Relay 1 COM

Relay 1 NC

Relay 1 NO

13 14 15 16 17

Gate Operator

OR

Electric Strike

OR

Magnetic Lock

24