DKS Enterprises 1817, 1815, 1803PC Controlling a Gate Operator and Two Pedestrian Doors or Gates

Models: 1817

1 67
Download 67 pages 63.03 Kb
Page 26
Image 26
2.3.3 Controlling a Gate Operator and Two Pedestrian Doors (or Gates)

2.3.3 Controlling a Gate Operator and Two Pedestrian Doors (or Gates)

The diagram below shows how it is possible to control a gate operator and two pedestrian doors or gates from the system. Relay 0 is typically used to control the gate operator and relays 1 and 2 are used to control pedestrian doors and/or gates. Note that the electric strike and the magnetic lock are powered from their own power supply. The relay 2 contact is set to either normally open (NO) for electric strikes, or normally closed (NC) for magnetic locks by placing the relay 2 contact shorting bar on either the NO or NC pins.

A variation of this diagram is for the system to control three doors, or two gate operators (entry and exit) and a door, or three gate operators.

Relay 0

Relay 0 NO Relay 0 NC Relay 0 COM

Relay 2 COM

Relay 2

Relay 1 COM

Relay 1 NC

Relay 1 NO

 

 

13

14

15

16

17

 

 

 

 

 

 

AND

 

 

 

 

 

 

AND

Magnetic Lock

Electric Strike

Gate Operator

26

Page 26
Image 26
DKS Enterprises 1817, 1815, 1803PC owner manual Controlling a Gate Operator and Two Pedestrian Doors or Gates