DKS Enterprises 1803PC Controlling a Gate Operator and Pedestrian Gate or Door, Electric Strike

Models: 1817

1 67
Download 67 pages 63.03 Kb
Page 25
Image 25
2.3.2 Controlling a Gate Operator and Pedestrian Gate (or Door)

2.3.2 Controlling a Gate Operator and Pedestrian Gate (or Door)

When controlling a gate operator and pedestrian gate (or door), relay 1 is typically used to control the gate operator while relay 2 is typically used to control the door or gate. Note that the electric strike and the magnetic lock are powered from their own power supply. The relay 2 contact is set to either normally open (NO) for electric strikes, or normally closed (NC) for magnetic locks by placing the relay 2 contact shorting bar on either the NO or NC pins.

A variation of this diagram is for the system to control two doors or two gates.

Relay 0 COM

Relay 0 NC

Relay 0 NO

Relay 0

Relay 2 COM

Relay 2

Relay 1 COM

Relay 1 NC

Relay 1 NO

13 14 15 16 17

Gate Operator

AND

Electric Strike

OR

Magnetic Lock

25

Page 25
Image 25
DKS Enterprises 1803PC, 1815, 1817 Controlling a Gate Operator and Pedestrian Gate or Door, Electric Strike, Magnetic Lock