2.3.4 Tracker Expansion Board Control

2.3.4 Tracker Expansion Board Control

When Tracker expansion boards are used with the system to control up to 16 additional entry points, relays 1 and 2 are designated as tracker command relays and connect to the Tracker expansion boards. In this diagram, relay 0 is used to control the gate operator and relays 1 and 2 are connected to the tracker expansion boards. The relay 2 shorting bar is set for normally open (NO) contacts.

For more information on Tracker expansion boards and wiring, refer to the Tracker Board Installation Manual, P/N 2351-065.

Relay 0

Relay 0 NO Relay 0 NC Relay 0 COM

Relay 2 COM

Relay 2

Relay 1 COM

Relay 1 NC

Relay 1 NO

 

 

13

14

15

16

17

 To Tracker Boards 9-16 To Tracker Boards 9-16