3.3.5 Touch-tone / Rotary-dial

This programming sequence will set the telephone entry system to dial out in either a touch-tone or rotary format. Generally, this will be set for touch-tone.

Factory setting = touch-tone.

1.Press *07 and enter the four digit MASTER CODE _ _ _ _ (beep).

2.Enter 0* (beep) for touch-tone or enter 1* (beep) for rotary.

3.Press 0# TOGETHER to end this programming step (beeeeeep).

3.3.6 Rotary-dial 9

This programming sequence sets which relay(s) will activate when the system receives a rotary-dial 9 open command from a residents rotary telephone. The system can be programmed so that only one relay will activate, or any combination of relays will activate. HINT: The relay that you designate as the primary relay should be programmed to activate from a rotary 9 command. To cause a relay to activate, enter a 1 in it's respective character slot, or enter a 0 to not activate the relay. Any combination of 1's or 0's is permissible. For example, entering 010 in step 3 will cause only relay 0 to activate. Entering 101 will cause both relay 0 and relay 2 to activate.

Factory setting = 010.

1.Press *51 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.Enter the three-digit (1's or 0's only) rotary 9 code _ _ _ then press * (beep).

3.Press 0# TOGETHER to end this programming step (beeeeeep).