DKS Enterprises 1803PC, 1815, 1817 owner manual General Programming, Relay Strike Time, Talk Time

Models: 1817

1 67
Download 67 pages 63.03 Kb
Page 34
Image 34
3.3 GENERAL PROGRAMMING

3.3 GENERAL PROGRAMMING

Proceed with the programming steps on the following pages only if PC programming will not be used.

3.3.1 Relay Strike Time

These steps will program Relay 0, Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4 second (enter 00 in step 4) up to 99 seconds by entering the desired time in seconds. If Tracker expansion boards are going to be used with this system, set Relay 2 strike time to 00 for Tracker boards 1-8. If more than 8 Tracker boards are being used, set Relay 1 strike time to 00 (for Tracker boards 9-16) and then set Relay 0 strike time for the desired time in seconds. In this application, Relay 0 becomes the PRIMARY relay that will open the door or gate after the tenant presses 9 on their telephone.

Factory setting for relay strike times are: Relay 0 = 99, Relay 1 = 01, Relay 2 = 01.

1.Press *03 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.Press 0* to set relay 0, or 1* to set relay 1, or 2* to set relay 2 strike time.

3.Enter the two-digit strike time _ _ (00-99) then press * (beep).

4.Repeat steps 2 and 3 to set other relay strike times.

5.Press 0# TOGETHER to end this programming step (beeeeeep).

3.3.2 Talk Time

This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit number. For example, to set a talk time of 20 seconds, enter 020 in step 3. The talk time set here does not affect the telephone numbers that are programmed under directory codes 0, 00, 000, 0000 and 1, 01, 001, 0001. The talk time for these two directory codes are factory set to the maximum. Phone numbers programmed under these directory codes should be reserved for management or emergency phone numbers that generally require longer conversations.

Factory setting for talk time = 60 seconds.

1.Press *08 and enter the four digit MASTER CODE _ _ _ _ (beep).

2.Enter three digits for talk time (seconds) _ _ _ (001-255) then press * (beep).

3.Press 0# TOGETHER to end this programming step (beeeeeep).

34

Page 34
Image 34
DKS Enterprises 1803PC, 1815 General Programming, Relay Strike Time, Talk Time, Factory setting for talk time = 60 seconds