SYMPTON

POSSIBLE SOLUTION(S)

 

 

Four-digit entry codes

Forgetting to press # first.

will not work.

Re-program the entry code ranges (3.7.3).

 

Entry codes will not

Re-program relay 0 low and high ranges (3.7.3).

activate relay 0.

 

 

 

Entry codes will not

Re-program relay 0 low and high ranges (3.7.3).

activate relay 1.

 

 

 

Entry codes will not

Re-program relay 0 low and high ranges (3.7.3).

activate relay 2.

 

 

 

Security levels or

Check that the SEC LEVEL pin is in place (4.12).

elevator control will

 

not function.

 

 

 

System emits a beep

Master code switch is in the ON position (4.7).

every 30 seconds.

 

 

 

DTMF tones are

The system CALL UP feature is turned on. Re-program this feature to turn it

heard 15 seconds

off (3.2.3).

after call is answered.

 

LCD Display shows:

The memory chip size (small chip) and the main memory storage ship (large

Reset Mem?

chip) do not match in memory size. By pressing 1, the main memory storage

chip will be matched to the memory size chip. All data in the main memory

1 = Y 2 = N

will be erased when this function is performed.

 

 

Press 2 to cancel out of this function.

LCD display shows:

The small chip in the PC board socket is for an 1818 system and cannot be

Need 1815(17) SM

used in the telephone entry system.

 

MEMCHIP

 

 

 

LCD is unreadable.

Adjust contrast (4.4, 4.5 and 4.6).

 

 

6.1.1 RS-232 Test

This test procedure will check the RS-232 hardware to determine a pass or fail mode. You will need two short pieces of wire to perform this test.

1.Open the cabinet of the telephone entry system and locate the RS-232 terminals in the upper left hand corner of the control board.

2.Short terminal 1 to terminal 2 using the first piece of wire.

3.Short terminal 3 to terminal 4 using the second piece of wire.

4.Press *17 and enter the four-digit master code _ _ _ _ (beep).

5.Press *.

PASS - The display will indicate: RS232 HARDWARE PASS and a long tone will be heard (Beeeeeep).

FAIL - The display will indicate RS232 HARDWARE FAIL and two short tones and then a long tone will be heard (Beep - Beep - Beeeeeep).

6. Remove the jumper wires from the terminal after performing this test.

61

Page 61
Image 61
DKS Enterprises 1803PC, 1815, 1817 owner manual 1 RS-232 Test, Will be erased when this function is performed

1815, 1803PC, 1817 specifications

DKS Enterprises has established itself as a leading provider of cutting-edge access control solutions, and among its notable offerings are the 1803PC, 1817, and 1815 models. These products stand out in the commercial security landscape, providing businesses with reliable and efficient entry management.

The DKS 1803PC is an advanced digital keyless entry system designed for commercial applications. Its primary feature is the easy-to-use keypad interface, which allows users to input their access codes directly. This model is equipped with a robust memory capable of storing up to 100 unique codes, making it suitable for locations with multiple users. Additionally, the 1803PC supports timed access, enabling businesses to set specific entry windows, which enhances security and access control.

The DKS 1817 model takes entry management a step further with its smart technology integration. It features Bluetooth capabilities that allow users to unlock doors via their smartphones, offering convenience and flexibility. The 1817 can be connected to various security devices, such as alarms and surveillance cameras, providing a comprehensive security ecosystem. It also includes a user-friendly mobile app that enables remote management of access permissions, ensuring that business owners can monitor and control entry points effectively from anywhere.

In contrast, the DKS 1815 model caters to businesses looking for a cost-effective yet reliable access solution. This model features a straightforward keypad interface similar to the 1803PC, but it is designed with essential functionalities to meet basic security needs. The 1815 supports up to 50 access codes and is ideal for smaller businesses or limited access areas. Its durable construction ensures longevity and requires minimal maintenance over time.

All three models employ DKS's proprietary technology that emphasizes durability and security. They are built to withstand harsh environmental conditions, making them suitable for both indoor and outdoor use. Each model adheres to stringent safety standards to protect against unauthorized access, ensuring the safety of personnel and assets.

In conclusion, DKS Enterprises' 1803PC, 1817, and 1815 models represent a diverse range of access control solutions tailored for various business needs. Their features focus on ease of use, advanced technology, and reliability, making them an excellent choice for organizations looking to enhance their security measures while streamlining access management.