ADDITIONAL INFORMATION FOR THE SAFE OPERATION OF THE CP65
To ensure proper operation and guard against potential shock hazard, the CP65 must be connected only to a properly wired, grounded (earthed) mains receptacle. If you are uncertain about the wiring of your mains outlet do not use it. Consult a qualified electrician. The power cord is supplied with either a standard U.S.A.
| International | U.S. |
live or hot | brown | black |
neutral | blue | white |
earth | green/yellow | green/yellow |
Before the power cord is connected to the CP65, ensure that a qualified electrician has wired the cord following the code.
U.S. Style Plugs
The ground terminal of the plug is connected directly to the chassis of the unit. For continued protection against electric shock, a
Connections for United Kingdom
WARNING: THIS APPARATUS MUST BE EARTHED.
As the colours of the cores in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
-the core which is coloured green and yellow must be connected to the terminal in the plug which is marked
with the letter E or by the earth symbol , or coloured green or green and yellow.
-the core which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
-the core which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
Voltage Setting | Fuse | Type |
100/120/140 VAC | 1.25 A | 1/4" x |
200/220/240 VAC | T 630 mA | 5 x 20mm time lag. |