Dynacord DMM 4650 owner manual Sequence example, Title, Save, command, Function

Models: DMM 4650

1 52
Download 52 pages 40.35 Kb
Page 24
Image 24
Sequence example

Title

Confirming “title” with the soft key “ok”, the name of the currently loaded sequence appears on the display. Using the cursor keys offers the possibility to enter a name of maximally 8 characters. The soft keys “A-a”and “spc” shift between the upper and the lower character case or enter a blank character, respectively.

After pressing the “EXIT” key (previous menu level), the question “store yes, no?” appears on the display. Acknowledging this question lets you save your new settings in a user preset.

Save

Confirming “save” with the soft key “ok” displays the number of the currently selected sequence. The cursor keys are used to enter the desired sequence number. Saving has to be confirmed using the soft key “y= yes”. Choosing “save” stores all modifications made in the above mentioned menu items into the selected user preset. Thus, individual saving the parameters in not necessary, since they remain in memory until another sequence is loaded.

If a factory preset sequence (S20, S21,...) is chosen for saving, only the ‘stop trigger" is stored.

Sequence example

Via “sequence” > “load” > S28 > “step list” the step function listing of sequence S28 with the name ‘Message 2’ is being selected, which shall serve as a simple example. The purpose of this sequence is the indication of a lamp signal and the playback of a previously recorded message to its end.

Step number

command

parameter

Function

1:

Out

C.1 set

indication lamp ON (relay C1)

2:

Sum=

off

input signal off

3:

DMM=

-2dB

volume DMM signal -2 dB

4:

Start

M02

start message M02

5:

wt

Audio

wait until message end

6:

End

 

Ende sequenz > stand-by

24

Page 24
Image 24
Dynacord DMM 4650 owner manual Sequence example, Title, Save, command, Function