Dynacord DMM 4650 owner manual Sequence Nummer

Models: DMM 4650

1 52
Download 52 pages 40.35 Kb
Page 40
Image 40
Manual background

Sequence Nummer

Title

Priority

Stopp trigger

 

S 28

 

“Message2”

80

off

Step

Command

Parameter

Start Message 2

 

 

1:

Out

C1 set

Description: Closing the signaling contact (C1 = message runs)

2:

Sum=

off

switches the audio controls to the priority of the message. After

3:

DMM=

-2dB

the message is finished the DMM 4650 returns to the stand-by

4:

Start

M 02

mode.

 

 

5:

wt

Audio

 

 

 

6:End

Sequence Nummer

Title

Priority

Stopp trigger

S 29

“EasyRec1”

80

C3 High >00,1s lat

Step

Command

Parameter

Starts the recording of Message 01 (remote recording),

1:

Out

C3 set

starts by briefly pressing the input C3 button (menu trigger),

2:

Record

M 01

stops by pressing the input C3 button again

3:

Out

C2 set

Description: Closing the signaling contact (C3 = remote recording

4:

Dly=

010,0 s

runs) starts erasing the message. After successful erasing the

5:

if

Stop

signaling contact C2 (=start recording) is being closed. The

6:

Nop

 

recording is terminated by switching the control input C3 (current

7:

if

Stop

input C3 on). If the termination of the recording mode is not

8:

Jump

14

recognized, the maximum duration is limited to 10 sec. Name and

9:

if

Delay

priority of the message stay unaltered and the DMM 4650 returns

10:

Jump

14

to the stand-by mode.

11:

if

Audio

 

12:End

13:Jump 07

14:Finish

15:

Out

C2 clr

16:

Jump

11

40

Page 40
Image 40
Dynacord DMM 4650 owner manual Sequence Nummer