CONNECTIONS
CONTROL INPUTS AND CONTROL OUTPUTS PORTS A - D
General:
Operation see page 21 (PORTS C, D are optional)
Each of the 4 ports (A, B, C, D) have 4 inputs and 4 outputs and a power source for supplying floating control keys or contacts.
The inputs and outputs are galvanic insulated from the DMM 4650 and the adjacent control lines. Port A has an additional fault output (relay contact) which, during normal operation, is always closed.
The DMM 4650 provides port connection through
Pin assignment for ports A, B, C, D: @ corresponds to A, B, C, D
pin | name | pin | name |
1 | - Batt. | OUT @1 | |
14 | - Batt. | OUT @2 | |
INP @1 | OUT @3 | ||
INP @2 | OUT @4 | ||
INP @3 | 11 | - Batt. | |
INP @4 | 24 | - Batt. | |
6 | - Batt. | Fault Out !!Only PORT A | |
19 | - Batt. | 13 | + Batt. (max. 90 mA) |
Control levels and currents:
Power source
Inputs:
The polarity of the control inputs is random.
L | = | low corresponds to | UINP | < ± 5V | IINP | < 1mA |
H | = | high corresponds to | UINP | > ± 10V | IINP | > 1.8mA |
|
| max. Uinp = ±31V |
|
|
|
|
30