Dynacord DMM 4650 owner manual Connections, Control levels and currents

Models: DMM 4650

1 52
Download 52 pages 40.35 Kb
Page 30
Image 30
CONNECTIONS

CONNECTIONS

CONTROL INPUTS AND CONTROL OUTPUTS PORTS A - D

General:

Operation see page 21 (PORTS C, D are optional)

Each of the 4 ports (A, B, C, D) have 4 inputs and 4 outputs and a power source for supplying floating control keys or contacts.

The inputs and outputs are galvanic insulated from the DMM 4650 and the adjacent control lines. Port A has an additional fault output (relay contact) which, during normal operation, is always closed.

The DMM 4650 provides port connection through 25-pole sub-D connectors (male).

Pin assignment for ports A, B, C, D: @ corresponds to A, B, C, D

pin

name

pin

name

1

- Batt.

7-20

OUT @1

14

- Batt.

8-21

OUT @2

2-15

INP @1

9-22

OUT @3

3-16

INP @2

10-23

OUT @4

4-17

INP @3

11

- Batt.

5-18

INP @4

24

- Batt.

6

- Batt.

12-25

Fault Out !!Only PORT A

19

- Batt.

13

+ Batt. (max. 90 mA)

Control levels and currents:

Power source -Batt. / +Batt. corresponds to a supply voltage of (20V - 31V) of the DMM 4650. For current limitation (fuse), a PTC resistor (positive temperature coefficient resistor) is provided at the +Batt connection of each port.

Inputs:

The polarity of the control inputs is random.

L

=

low corresponds to

UINP

< ± 5V (0-5V)

IINP

< 1mA (0-1mA)

H

=

high corresponds to

UINP

> ± 10V (10-31V)

IINP

> 1.8mA (1.8-7mA)

 

 

max. Uinp = ±31V

 

 

 

 