Dynacord DMM 4650 owner manual List of factory preset sequences

Models: DMM 4650

1 52
Download 52 pages 40.35 Kb
Page 37
Image 37
List of factory preset sequences

List of factory preset sequences

Sequence Nummer

S 20

Step Manual background Command Manual background Parameter

1:Break

2:End

Title

Priority

Stopp trigger

“stop all”

99

off

Stops all running sequences

Description: Stops all running sequences with low priorities (all factory presets). Upon completion the DMM 4650 returns to the stand-by mode.

Sequence Nummer

Title

Priority

Stopp trigger

S 21

“Alarmtxt”

97

off

Step

Command

Parameter

1:

Out

A1 set

2:

wt

In A1 High

3:

Out

B4 clr

4:

Out

B2 set

5:

Out

B3 set

6:

Out

A2 set

7:

Sum=

off

8:

DMM=

-2dB

9:

Start

M 00

10:

wt

Audio

11:End

Start alarm text (message 00) once

Description: Turns the sound reinforcement system on (relay A1) and waits for acknowledgment (input A1 = system ready). When the system is ready, the output B4 (music program off) is opened and B2, B3 (mandatory reception E, D) is closed. After closing the signaling contact (A2 = alarm text running) the audio controls are set to alarm text priority. The alarm text (M00) is given out. After the transmission of the message is completed, the se- quence is finished and the device returns to the stand-by mode, i. e. all line and relay contact settings re-enter the status, prior to the start of the sequence.

Sequence Nummer

Title

Priority

Stopp trigger

S 22

“DIN-Alrm”

93

off

Step

Command

Parameter

1:

Out

A1 set

2:

wt

In A1 High

3:

Out

B4 clr

4:

Out

B2 set

5:

Out

B3 set

6:

Out

A3 set

7:

Sum=

off

8:

DMM=

-5dB

9:

Start

A 20

10:

wt

Audio

11:End

Start continuous DIN alarm (siren 1200 Hz - 500 Hz, per second)

Description: Turns the sound reinforcement system on (relay A1) and waits for acknowledgment (input A1 = system ready). When the system is ready, the output B4 (music program off) is opened and B2, B3 (mandatory reception E, D) is closed. After closing the signaling contact (A3 = alarm signal running) the audio controls are set to alarm text priority. The alarm signal (A20) is outputted and runs continuously until it is stopped by a sequence with a higher priority (e.g. S20). The control of the settings and relay contacts is taken over by the stop sequence and upon completion the DMM 4650 returns to stand-by mode.

37

Page 37
Image 37
Dynacord DMM 4650 owner manual List of factory preset sequences