Dynacord DMM 4650 owner manual Priority

Models: DMM 4650

1 52
Download 52 pages 40.35 Kb
Page 43
Image 43
Manual background

Sequence Nummer

Title

Priority

Stopp trigger

S 34

“gen-emgc”

95

off

Step

Command

Parameter

1:

Out

A1 set

2:

wt

In A1 High

3:

Out

B4 clr

4:

Out

B2 set

5:

Out

B3 set

6:

Out

A3 set

7:

Sum=

off

8:

DMM=

-5dB

9:

Start

A 30

10:

wt

Audio

11:

Start

A 31

12:

wt

Audio

13:

Jump

09

14:End

Ship alarm “General Emergency”

Description: Turns the sound reinforcemnet system’s power on (relay A1) and waits for acknowledgment (input A1 = system ready). When the system is ready, the output B4 (music program off) is opened and B2, B3 (mandatory reception E, D) gets closed. Closing the signaling contact (A3 = alarm signal running) swit- ches the audio controls to the alarm signal’s priority. The signal sequence is defined as follows: 7 packages 1.5 sec. 800 Hz tone with 1.5 sec. break (A30) followed by a 4.5 sec. tone with 1.5 sec. break (A31). The sequence runs continuously until it is stopped by a sequence with a higher priority (e. g. S 20). The control of settings and relay contacts is taken over by the stop sequence. After the stop sequence ends, the DMM 4650 returns to stand-by mode.

Sequence Nummer

S 35

Step

Command

Parameter

1:

Out

A1 set

2:

wt

In A1 High

3:

Out

B4 clr

4:

Out

B2 set

5:

Out

B3 set

6:

Out

A3 set

7:

Sum=

off

8:

DMM=

-5dB

9:

Start

A 32

10:

wt

Audio

11:

Start

A 31

12:

wt

Audio

13:

Jump

09

14:End

Title

Priority

Stopp trigger

“fireship”

95

off

Ship alarm “Fire”

Description: Turns the sound reinforcement system’s power on (relay A1) and waits for acknowledgment (input A1 = system ready). When the system is ready, the output B4 (music program off) is opened and B2, B3 (mandatory reception E, D) is closed. Closing the signaling contact (A3 = alarm signal running) swit- ches the audio controls to the alarm signal’s priority. The signal sequence is defined as follows: 1 package 1.5 sec. 800 Hz tone with 1.5 sec. break (A32) followed by a 4.5 sec. tone with 1.5 sec. break (A31). The sequence runs continuously until it is stopped by a sequence with a higher priority (e. g. S 20). The control of settings and relay contacts is taken over by the stop sequence. When the stop sequence ends, the DMM 4650 returns to stand- by mode.

43

Page 43
Image 43
Dynacord DMM 4650 owner manual Priority