Sequence Nummer

Title

Priority

Stopp trigger

S 36

“ManMorse”

95

off

Step

Command

Parameter

1:

Out

A1 set

2:

wt

In A1 High

3:

Out

B4 clr

4:

Out

B2 set

5:

Out

B3 set

6:

Out

A3 set

7:

Sum=

off

8:

DMM=

-5dB

9:

wt

In D4 High

10:

Start

A 33

11:

wt

In D4 Low

12:Break

13:Jump 09

14:End

Ship alarm “Manual Morse key”

Description: Turns the sound reinforcement system’s power on (relay A1) and waits for acknowledgment (input A1 = system ready). When the system is ready, the output B4 (music program off) is opened and B2, B3 (mandatory reception E, D) is being closed. Closing the signaling contact (A3 = alarm signal running) switches the audio controls to the alarm signal’s priority. A continuous tone (800 Hz = A33) starts when a current is present at the control input D4 and stops after releasing the key. The sequence runs continuously until it is stopped by a sequence with a higher priority (e. g. S 20). The control of settings and relay contacts is taken over by the stop sequence. After the stop sequence ends, the DMM 4650 returns to stand-by mode.

Sequence Nummer

S 37

Step

Command

Parameter

1:

Out

A1 set

2:

wt

In A1 High

3:

Out

B4 clr

4:

Out

B2 set

5:

Out

B3 set

6:

Out

A3 set

7:

Sum=

off

8:

DMM=

-5dB

9:

Count

0005

10:

Start

A 28

11:

wt

Audio

12:

Dly=

004,0s

13:

wt

Delay

14:

if

Count

15:End

16:Jump 10

17:End

Title

Priority

Stopp trigger

“Telefon”

95

off

Telephone bell

Description: Turns the sound reinforcemnet system’s power on (relay A1) and waits for acknowledgment (input A1 = system ready). When the system is ready, the output B4 (music program off) is opened and B2, B3 (mandatory reception E, D) is closed. Closing the signaling contact (A3 = alarm signal running) swit- ches the audio controls to the alarm signal’s priority. The signal sequence is defined as follows: 1 sec. signal (A28), 4 sec. break. It is being repeated five times. Using different signal periods offers the opportunity to realize a code call system. When the call signal ends, the DMM 4650 returns to stand-by mode.