In stand-by mode the DMM 4650 runs a number of test routines in order to detect device faults at an early stage. Errors are indicated by the flashing of the green POWER LED. With fatal errors or when errors start to appear more often the blinking of the LED gets faster and the fault relay drops. At the same time, the audio input is connected directly to the output via the bypass relay.

The menu “self test” provides a listing of error numbers and occurence of the following mesages:

No:

Error Name

Function test

1

Reset

Power-On counter, no message displayed

2

Software

faulty micro processor interrupt

3

Modul-ID

changing number and activity of control ports (A-D) during power-on

4

+/- 15V

tests internal supply-voltage ± 15V

5

Bypass

function of audio bypass relay (hardware and software)

6

Fault

function of fault relay (hardware and software)

7

User-mem

data error of passwords and their priorities

8

Trig-mem

data error in trigger settings

9

Sequ-mem

data error in user presets of sequences

10

Stop-mem

data error in user settings of stop triggers

11

Alrm-mem

data error in alarm user presets

12

Gong-mem

data error in gong user presets

13

Msg-dir

data error in message file management

14

Msg-chsu

data error in message audio data (see also “message” on page 14 “*”)

15

ARS-RAM

communication error in DSP processor

16

ARS-mod

software error in DSP processor

17

Flash

tests for a changed number of flash memory cards

18

Block

faulty blocks in flash memory has been occurred later

19

EEPROM

error at writing into EEPROM

20

ROM

data modification of the microprocessor’s EPROM