Dynacord DMM 4650 owner manual Priority

Models: DMM 4650

1 52
Download 52 pages 40.35 Kb
Page 42
Image 42
Manual background

Sequence Nummer

Title

Priority

Stopp trigger

S 32

“Ansage”

80

D3 Low >00,1s stc

Step

Command

Parameter

Announcement via recording input DMM 4650 as long as the

1:

Out

D3 set

key is being pressed (System input -20 dB).

2:

Sum=

-20dB

Description: Closing the signaling contact (D3 = announcement

3:

DMM=

-3dB

running) switches the audio controls of the sum input to -20 dB

4:

Start

Ann.

and the controls of the announcement to -3dB. After the correct

5:

wt

Stop

level was set once in the operation menu (announcement), the

6:

End

 

announcement is made via one of the DMM 4650’s recording

 

 

 

inputs. When the message has ended the DMM 4650 returns to

 

 

 

the stand-by mode.

Sequence Nummer

Title

Priority

Stopp trigger

S 33

“BZB-ABC”

95

off

Step

Command

Parameter

1:

Out

A1 set

2:

wt

In A1 High

3:

Out

B4 clr

4:

Out

B2 set

5:

Out

B3 set

6:

Out

A3 set

7:

Sum=

off

8:

DMM=

-5dB

9:

Count=

0003

10:

Start

A 27

11:

wt

Audio

12:

Dly=

012,0s

13:

wt

Delay

14:

if

Count

15:

Jump

17

16:

Jump

10

17:

Dly=

006,0s

18:

wt

Delay

19:

Count=

0003

20:

Dly=

012.0s

21:

wt

Delay

22:

Start

A 27

23:

wt

Audio

24:

if

Count

25:End

26:Jump 20

27:End

BZB ABC alarm

Description: Turns the sound reinforcement system’s power on (relay A1) and waits for acknowledgment (input A1 = system ready). When the system is ready, the output B4 (music program off) is opened and B2, B3 (mandatory reception E, D) is closed. Closing the signaling contact (A3 = alarm signal running) swit- ches the audio controls to the alarm signal’s priority. The signal sequence is defined as follows: 1 minute siren interrupted by two breaks (=5 * l2sec, siren = 330 - 420 Hz), break 30 seconds and repeating of the signal sequence (total duration 150 sec.); the utilized alarm preset is A 27 = 12 sec. siren. Afterwards the DMM 4650 returns to the stand-by mode.

42

Page 42
Image 42
Dynacord DMM 4650 owner manual Priority