2.Up to 2 ft / 0.6 m between adjacent side-by-side modules in a cluster

User-supplied Cat-5 crossover cable.

Connect between unused Signal Link jacks (Neutrik EtherCon) on horizontally adjacent ends of the modules.

Crossover Cable Wiring

STANDARD END PINS

1

2

3

4

5

6

7

8

CROSSOVER END PINS

3

6

1

4

5

2

7

8

5.1.5 DAISY CHAINING COMPUTER AND AUDIO SIGNALS BETWEEN CLUSTERS

Any distance (within EIA-485 limitations) between clusters: 2-conductor shielded cable

Audio A, Audio B, and EIA-485

EIA-485

AUDIO A

AUDIO B

Connect in parallel to the incoming signal cables on one module in the first cluster and connect to the same signal ports on one module in the next cluster. Use the supplied 3-pin Phoenix Contact terminal plugs.

Figure 5.1.5 Linking > 2 ft / 0.6 m

EIA-485 TERMINATE SWITCH

Recommended Conductor Gauge:

24 AWG to 18 AWG / 0.2 mm to 1 mm

ON

5.1.6 EIA-485 TERMINATE SWITCH

EIA-485 termination has special requirements and limitations. See Appendix 8.3 for details.

Single Cluster:

Set the EIA-485 Terminate Switch on the module (connected via the Phoenix connector) to “ON”.

EIA-

 

TERMINATE

OFF

485

LIFT

AUD

GROUND

 

IO

 

LIFT

 

Figure 5.1.6a EIA-485 Terminate Switch

Multiple Clusters:

Set the EIA-485 Terminate Switch to “ON” ONLY on the module (connected via the Phoenix connector) at the end of the EIA-485 cable run furthest from the computer. Set all other Terminate Switches to “OFF”.

CAUTION: Engaging the EIA-485 Terminate Switch on more than one module on the EIA-485 cable run can cause intermittent or nonexistent communications.

 

 

DSA

 

 

CLUSTERS

 

RS-232

 

 

OR USB

TERMINATE

 

TO EIA-485

 

SWITCH "OFF"

 

CONVERTER

 

 

PC

 

TERMINATE

 

 

SWITCH "OFF"

TERMINATE

SWITCH "ON"

Figure 5.1.6b EIA-485 Network Diagram

15

Page 19
Image 19
EAW DSA230i, DSA250i owner manual Recommended Conductor Gauge AWG to 18 AWG / 0.2 mm to 1 mm