Coverage is incorrect | Improper | Using DSAPilot, ensure the |
|
| desired beamwidth and aiming |
|
| angle are correct. |
Coverage is incorrect | Module upside down | Using DSAPilot to active the |
|
| module’s LED indicator, ensure |
|
| the up/down enclosure orientation |
|
| is correct for the application. |
Distorted sound | Failed internal component(s) | Using DSAPilot’s Service |
|
| Mode, check the operation of each |
|
| amplifier and driver. |
Distorted sound | Excessive levels | Using DSAPilot, monitor the |
|
| DSAi signal path to check for |
|
| clipping at all monitoring points. |
Distorted sound | Bad input signal | Use a substitute amplifier and |
|
| module to check the quality |
|
| of the input signal to the DSAi |
|
| Series module. |
|
|
|
No computer communication | Incorrect PC | Follow the instructions in the |
|
| DSAPilot Help File for configuring |
|
| PC communications for DSAPilot. |
No computer communication | Incorrect connections | Check that |
|
| both the computer and the module |
|
| is wired correctly for the +/- signal |
|
| wires and cable shield. |
No computer communication | Incorrect termination | Ensure that a termination is |
|
| engaged at the |
|
| computer and the Terminate Switch |
|
| is “ON” at the module at the |
|
| farthest end of the |
|
| run. All other Terminate Switches |
|
| should be “OFF”. |
No computer communication | Module is powered off | Ensure the module is powered on. |
No computer communication or | Improper network | Ensure the |
only with some modules | configuration | termination conforms to the notes |
|
| in Section 8.3. |
No computer communication | Improper link connections | Ensure the |
|
| with some modules between |
|
| modules and/or the supplied |
|
| Signal Link Cables are connected |
|
| between modules as detailed in this |
manual. | 35 |
|