Connect the AC power cord to the projector and turn on the projector.
Turn off the projector and unplug the AC power cord. Allow the projector to cool for at least 45 minutes.
Remove the screw with a screwdriver, and remove the lamp cover.
Loosen 2 screws of the lamp with a screwdriver and pull the handle out to remove the lamp.

Maintenance and Cleaning

Lamp Replacement

When the life of the projection lamp draws to an end, the LAMP REPLACE indicator emits yellow light. If this indicator emits yellow light, replace the lamp with a new one promptly.

This indicator emits yellow light when the life of the projection lamp draws to an end.

Top Control

W

LAMP

REPLACE

CAUTION

Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can become very hot.

CAUTION

For continued safety, replace with a lamp of the same type. Do not drop the lamp or touch the glass bulb! The glass can shatter and may cause injury.

Follow these steps to replace the lamp.

1

2

3

4 Replace the lamp with a new one and tighten the 2 screws back into position. Make sure that the lamp is set properly. Replace the lamp cover and tighten the screw.

5

6 Reset the Lamp replacement counter.

See “Lamp Replacement Counter” on the next page.

Lamp Cover

Screw

Screw

Lamp

Handle

Screw

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.

Model No. of your projector

:

LC-SD15

Replacement Lamp Type No.

:

POA-LMP78

 

 

 

(Service Parts No. 610 317 7038)