E L A N H O M E S Y S T E M S | DT22 INSTALLATION MANUAL |
Config Preset Dump
Query:
&DT,CH,CONFIG,PRESETS,DUMP<cr>
Function:
Outputs the current preset information stored in the unit.
The information is in an XML format.
Config Overrides Dump
Query:
&DT,CH,CONFIG,OVERRIDES,DUMP<cr>
Function:
Outputs the current override information stored in the unit.
The information is in an XML format.
Config Factory Reset
Command:
Function:
Sets all configuration to the factory defaults.
Unit ID
Command: &DT,CH,CONFIG,UNITID,x<cr> x = 1, 2
Function:
Sets the unit ID of the DT22.
DT22 must be rebooted for change to take effect.
Query:
&DT,CH,CONFIG,UNITID,?<cr>
Function:
Queries the current ID of the DT22.
Response:
*DT,CH,CONFIG,UNITID,1<cr> or
*DT,CH,CONFIG,UNITID,2<cr>
Config RS232 Unsolicited Feedback On/Off
Command:
&DT,CH,CONFIG,RS232,UFB,ON<cr>
© ELAN Home Systems 2009 • All rights reserved. | Page 61 |