17 electrolux outdoor unit installation
refrigerant pipe connection electrolux 18
Refrigerant pipe connection
Settlement of outdoor unit
Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount.
B
A |
Air inlet |
Air |
inlet |
Flaring work
Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work using the following procedure:
Pipe
MODEL
700x535x235
685x430x260
780x540x250
760x590x285
820x600x345
845x695x335
895x860x330
Drain joint installation
Fit the seal into the drain elbow, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely assemble them.
Connecting the drain joint with an extension drain hose (Locally purchased), in case of the water draining off the outdoor unit during the heating mode.
Seal
+ =
| Air outlet | ||||
A (mm) |
|
|
|
| B (mm) |
458 | 250 | ||||
460 | 276 | ||||
549 | 276 | ||||
530 | 290 | ||||
523 | 340 | ||||
560 | 335 | ||||
590 | 333 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Base pan hole of outdoor unit
1.Cut the pipes and the cable. A) Use the piping kit accessory or pipes purchased locally.
B) Measure the distance between the indoor and the outdoor unit.
C) Cut the pipes a little longer than the measured distance.
D) Cut the cable 1.5m longer than the pipe length.
2.Burr removal
A)Completely remove all burrs from the cut cross section of pipe/tube.
B)Put the end of the copper tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.
3. Putting nut on
A)Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.(not possible to put them on after flaring work)
CorrectWrong
Oblique Roughness Burr
Pipe
Reamer Point
down
Flare nut
Cooper tube
Seal | Drain joint | Drain pipe |