3.Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping.

4.Push the lower part of the indoor unit up on the wall, then move the indoor unit from side to side, up and down to check if it is hooked securely.

Cushioning material

outdoor unit installation electrolux 16

Outdoor unit installation

1. Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.

2. Determine the air outlet direction where the discharged air is not blocked. In the case that the installation place is exposed to strong wind such as a seaside, make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates.

3.Specially in windy area, install the unit to prevent the admission of

Piping and wrapping

1.Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown.

2.Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room. Do not put anything else in the box.

Indoor unit

Cable

de conexión

Drain hose

Ponding box

Pipe room

Connective pipe

Wrapping belt

wind. If need suspending installation, the installation bracket should accord with technique requirement in the installation bracket diagram.

4. The installation wall should be solid

Strong wind

brick, concrete or the same intensity construction, or actions to reinforce, damping supporting should be taken. The connection between bracket and wall, bracket and the air conditioner should be firm, stable and reliable.

5.Be sure there is no obstacle which block radiating air.

1.Connect the indoor unit first, then the outdoor unit.

2.Do not allow the piping to let out from the back of the indoor unit.

3.Be careful not to let the drain hose slack.

4.Heat insulated both of the auxiliary piping.

5.Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.

6.Never intercross nor intertwist the power wire with any other wiring.

7.Run the drain hose sloped downward to drain out the condensed water smoothly.