SAM Active Shelf Manager Discrete Sensors FRU Information and Sensor Data Records
AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C) 113
2.4.6.5 BMC Watchdog Sensor

The following table describes the discrete BMC Watchdog sensor available on the Active SAM.

2.4.6.6 System Event

The following table describes the discrete system event sensor available on the Active SAM.

Table 2-113 Sensor No. 132 (0x84) BMC Watchdog

Feature Raw Value/Description Interpreted Value
Sensor Name BMC Watchdog
Type of Measurement State of the BMC Watchdog on
the Active SAM
Class Discrete
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x23 IPMI Watchdog 2
Sensor Owner LUN 0x00
Entity ID 0xF0 PICMG Shelf Management
Controller
Entity Instance 0x01
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x0F, 0x01
Deassertion Event Mask (bytes
17,18)
0x00, 0x00
Discrete Reading Mask (bytes
19, 20)
0x0F, 0x01 Supports 5 States
Reading Definition According to IPMI 1.5

Table 2-114 Sensor No. 133 (0x85) SYSTEM EVENT

Feature Raw Value/Description Interpreted Value
Sensor Name System Event
Type of Measurement Presence
Class Discrete
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x12 System Event
Sensor Owner LUN 0x00
Entity ID 0xF0 PICMG Shelf Management
Controller
Entity Instance 0x01
Rearm mode Auto