FRU Information and Sensor Data RecordsActive SAM1000 Analog Sensors

Table 2-66 Sensor No. 193 (0xC1) FT 6 Fan 2 12 V (continued)

Feature

Raw Value/Description

Interpreted Value

 

 

 

Entity ID

0x1E

Cooling Unit

 

 

 

Entity Instance

0x65

 

 

 

 

Rearm mode

 

Auto

 

 

 

Hysteresis support

 

No

 

 

 

Threshold access support

 

Readable/Settable

 

 

 

Event message control

 

Entire Sensor only

 

 

 

Readable and Settable

0x36, 0x00

Upper and Lower Critical and

threshold mask (bytes 19, 20)

 

Non-recoverable Thresholds

 

 

are Readable

 

 

 

Reading Type

 

Unsigned

 

 

 

Lower critical and non-

0x50, 0x4c

(6.88, 6.536) Volts

recoverable thresholds

 

 

 

 

 

Upper critical and non-

0x9F, 0xA0

(13.674, 13.76) Volts

recoverable thresholds

 

 

 

 

 

Table 2-67 Sensor No. 194 (0xC2) FT 6 Fan 2 VBias

Feature

Raw Value/Description

Interpreted Value

 

 

 

Sensor Name

FT 6 Fan 2 VBias

 

 

 

 

Device

 

 

 

 

 

Sensor Type

0x02

Voltage

 

 

 

Class

0x01

Threshold

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

Entity ID

0x1E

Cooling Unit

 

 

 

Entity Instance

0x65

 

 

 

 

Rearm mode

 

Auto

 

 

 

Hysteresis support

 

No

 

 

 

Threshold access support

 

Readable/Settable

 

 

 

Event message control

 

Entire Sensor only

 

 

 

Readable and Settable

0x36, 0x00

Upper and Lower Critical and

threshold mask (bytes 19, 20)

 

Non-recoverable Thresholds

 

 

are Readable

 

 

 

Reading Type

 

Unsigned

 

 

 

Lower critical and non-

0x73, 0x71

(9.89, 9.718) Volts

recoverable thresholds

 

 

 

 

 

Upper critical and non-

0x87, 0xA5

(11.61, 14.19) Volts

recoverable thresholds

 

 

 

 

 

84

AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)

Page 84
Image 84
Emerson AXP1406, AXP1600 manual Sensor No 0xC2 FT 6 Fan 2 VBias