FRU Information and Sensor Data RecordsPower Entry Module Analog Sensors

Table 2-140 Sensor No. 13 +8 V PEM Feed 2

Feature

Raw Value/Description

Interpreted Value

 

 

 

Sensor Name

+8 V PEM Feed 2

 

 

 

 

Device

 

 

 

 

 

Sensor Type

0x02

Voltage

 

 

 

Class

0x01

Threshold

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

Entity ID

0x0A

Power Supply

 

 

 

Entity Instance

0x60

 

 

 

 

Rearm mode

 

Auto

 

 

 

Hysteresis support

 

Readable/Settable

 

 

 

Threshold access support

 

Readable/Settable

 

 

 

Event message control

 

Entire Sensor only

 

 

 

Readable threshold mask,

0x3F, 0x3F

Upper and Lower Non-Critical,

Settable threshold mask (bytes

 

Critical and Non-Recoverable

19, 20)

 

Thresholds are Readable and

 

 

Settable

 

 

 

Reading Type

 

Unsigned

 

 

 

Lower Non-Critical, Critical and

0x87, 0x7D, 0x74

(7.02, 6.5, 6.032) Volts

Non-Recoverable thresholds

 

 

 

 

 

Upper Non-Critical, Critical and

0xAE, 0xB7, 0xC1

(9.048, 9.516, 10.036) Volts

Non-Recoverable thresholds

 

 

 

 

 

Table 2-141 Sensor No. 15 +8 V PEM Feed 1

Feature

Raw Value/Description

Interpreted Value

 

 

 

Sensor Name

+8 V PEM Feed 1

 

 

 

 

Device

 

 

 

 

 

Sensor Type

0x02

Voltage

 

 

 

Class

0x01

Threshold

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

Entity ID

0x0A

Power Supply

 

 

 

Entity Instance

0x60

 

 

 

 

Rearm mode

 

Auto

 

 

 

Hysteresis support

 

Readable/Settable

 

 

 

Threshold access support

 

Readable/Settable

 

 

 

Event message control

 

Entire Sensor only

 

 

 