FRU Information and Sensor Data RecordsSAM Active Shelf Manager Discrete Sensors

Table 2-129 Sensor No. 235 (0xEB) FT 6 -48 V Fuse

Feature

Raw Value/Description

Interpreted Value

 

 

 

Sensor Name

FT 6 -48 V Fuse

 

 

 

 

Type of Measurement

 

State of Fuse

 

 

 

Class

 

Discrete

 

 

 

Event/Reading Type

0x03

'digital' Discrete

 

 

 

Sensor Type

0xC0

OEM-reserved

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

Entity ID

0x1E

Cooling Unit

 

 

 

Entity Instance

0x65

 

 

 

 

Rearm mode

 

Auto

 

 

 

Event message control

 

Entire Sensor only

 

 

 

Assertion Event Mask (bytes

0x02, 0x00

 

15,16)

 

 

 

 

 

Deassertion Event Mask (bytes

0x00, 0x00

 

17,18)

 

 

 

 

 

Discrete Reading Mask (bytes

0x03, 0x00

Supports 2 Successive States

19, 20)

 

 

 

 

 

Reading Definition

 

According to Pigeon Point

 

 

 

Table 2-130 Sensor No. 236 (0xEC) FT 7 -48 V Fuse

Feature

Raw Value/Description

Interpreted Value

 

 

 

Sensor Name

FT 7 -48 V Fuse

 

 

 

 

Type of Measurement

 

State of Fuse

 

 

 

Class

 

Discrete

 

 

 

Event/Reading Type

0x03

'digital' Discrete

 

 

 

Sensor Type

0xC0

OEM-reserved

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

Entity ID

0x1E

Cooling Unit

 

 

 

Entity Instance

0x66

 

 

 

 

Rearm mode

 

Auto

 

 

 

Event message control

 

Entire Sensor only

 

 

 

Assertion Event Mask (bytes

0x02, 0x00

 

15,16)

 

 

 

 

 

Deassertion Event Mask (bytes

0x00, 0x00

 

17,18)

 

 

 

 

 

Discrete Reading Mask (bytes

0x03, 0x00

Supports 2 Successive States

19, 20)

 

 

 

 

 

Reading Definition

 

According to Pigeon Point

 

 

 

122

AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)

Page 122
Image 122