Emerson and Pigeon Point OEM CommandsSupported IPMI Commands

This command requests a SAM switchover.

Table 1-16 Shelf Manager Switchover (Cmd = 0x02)

 

Byte

Data field

 

 

 

Request data

1

Pigeon Point Systems IANA Enterprise number, LSB first

 

 

 

 

 

2

0x0A

 

 

 

 

 

 

3

0x40

 

 

 

0x00

 

 

 

 

 

 

4

Flags

 

 

 

0x00

Switchover, but do not reboot the active Shelf Manager

 

 

0x01

Switchover, and reboot the active Shelf Manager

 

 

 

Response data

1

Completion Code

 

 

 

 

 

2

0x0A

 

 

 

 

 

 

3

0x40

 

 

 

 

 

 

4

0x00

 

 

 

 

 

This command instructs the SAM to transition a FRU to the M0 (not installed) state.

Table 1-17 Set FRU Extracted (Cmd = 0x03)

 

Byte

Data field

 

 

 

Request data

1

Pigeon Point Systems IANA Enterprise number, LSB first

 

 

 

 

 

2

0x0A

 

 

 

 

 

 

3

0x40

 

 

 

0x00

 

 

 

 

 

4

IPMB address

 

 

 

 

5

FRU Id

 

 

 

 

6

Force option

 

 

0x00

Only extract specified FRU if it is in M7 state

 

 

0x01

Extract the specified FRU regardless of its current state

 

 

 

Response data

1

Completion Code

 

 

 

 

2

Pigeon Point Systems IANA Enterprise number, LSB first

 

 

 

 

 

3

0x0A

 

 

 

 

 

 

4

0x40

 

 

 

0x00

 

 

 

 

 