Power Entry Module Analog Sensors

FRU Information and Sensor Data Records

 

 

2.5.5.1Voltage Sensors

The following sensors measure voltages of the PEM.

Table 2-135 Sensor No. 2 +3.3 V

Feature

Raw Value/Description

Interpreted Value

 

 

 

Sensor Name

+3.3 V

 

 

 

 

Device

 

 

 

 

 

Sensor Type

0x02

Voltage

 

 

 

Class

0x01

Threshold

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

Entity ID

0x0A

Power Supply

 

 

 

Entity Instance

0x60

 

 

 

 

Rearm mode

 

Auto

 

 

 

Hysteresis support

 

Readable/Settable

 

 

 

Threshold access support

 

Readable/Settable

 

 

 

Event message control

 

Entire Sensor only

 

 

 

Readable threshold mask,

0x3F, 0x3F

Upper and Lower Non-Critical,

Settable threshold mask (bytes

 

Critical and Non-Recoverable

19, 20)

 

Thresholds are Readable and

 

 

Settable

 

 

 

Reading Type

 

Unsigned

 

 

 

Lower Non-Critical, Critical and

0xD8, 0xD4, 0xD1

(3.1104, 2.0528, 3.0096) Volts

Non-Recoverable thresholds

 

 

 

 

 

Upper Non-Critical, Critical and

0xF4, 0xF7, 0xFA

(3.5136, 3.5568, 3.6) Volts

Non-Recoverable thresholds

 

 

 

 

 

Table 2-136 Sensor No. 3 +8 V

 

Feature

Raw Value/Description

Interpreted Value

 

 

 

 

 

 

 

Sensor Name

+8 V Backup Out

 

 

 

 

 

 

 

 

Device

 

 

 

 

 

 

 

 

 

Sensor Type

0x02

Voltage

 

 

 

 

 

 

 

Class

0x01

Threshold

 

 

 

 

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

 

 

 

 

Entity ID

0x0A

Power Supply

 

 

 

 

 

 

 

Entity Instance

0x60

 

 

 

 

 

 

 

 

Rearm mode

 

Auto

 

 

 

 

 

 

 

Hysteresis support

 

Readable/Settable

 

 

 

 

 

 

 

Threshold access support

 

Readable/Settable

 

 

 

 

 

 

 

Event message control

 

Entire Sensor only

 

 

 

 

 

 

 

 

 

 

 

AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)

127

Page 127
Image 127
Emerson AXP1600, AXP1406 manual Sensor No +3.3, Sensor No +8