AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records SAM Active Shelf Manager Discrete Sensors
118
Table 2-122 Sensor No. 227 (0xE3) Fan Tray 8
Feature Raw Value/Description Interpreted Value
Sensor Name Fan Tray 8
Type of Measurement Fan Tray 8 Presence
Class Discrete
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Sensor Owner LUN 0x00
Entity ID 0x1E Cooling Unit
Entity Instance 0x67
Rearm mode Auto
Event message control Entire Sensor only
Assertion Event Mask (bytes
15,16)
0x03, 0x00
Deassertion Event Mask (bytes
17,18)
0x00, 0x00
Discrete Reading Mask (bytes
19, 20)
0x03, 0x00 Supports 2 Successive States
Reading Definition According to IPMI 1.5
An additional Fan Tray Presence sensor supports the SAM used in the AXP1600 shelf.Table 2-123 Sensor No. 228 (0xE4) Fan Tray 9, AXP1600
Feature Raw Value/Description Interpreted Value
Sensor Name Fan Tray 9
Type of Measurement Fan Tray 8 Presence
Class Discrete
Event/Reading Type 0x6F Sensor-specific
Sensor Type 0x25 Entity Presence
Sensor Owner LUN 0x00
Entity ID 0x1E Cooling Unit
Entity Instance 0x68
Rearm mode Auto
Event message control Entire Sensor only