FRU Information and Sensor Data RecordsSAM Physical Shelf Manager Analog Sensors

Table 2-6 Sensor No. 4 +12 V Voltage (continued)

Feature

Raw Value/Description

Interpreted Value

 

 

 

Settable threshold mask (bytes

0x12, 0x12

Upper and Lower Critical

19, 20)

 

Thresholds are Readable and

 

 

Settable

 

 

 

Reading Type

 

Unsigned

 

 

 

Lower critical threshold

0x00

0 Volts

 

 

 

Upper critical threshold

0xFF

15.81 Volts

 

 

 

Table 2-7 Sensor No. 5 +1.8 V

Feature

Raw Value/Description

Interpreted Value

 

 

 

Sensor Name

+1.8 V

 

 

 

 

Type of measurement

 

Voltage

 

 

 

Device

 

 

 

 

 

Sensor Type

0x02

Voltage

 

 

 

Class

0x01

Threshold

 

 

 

Sensor Owner LUN

0x00

 

 

 

 

Entity ID

0xF0

PICMG Shelf Management

 

 

Controller

 

 

 

Entity Instance

0x60

 

 

 

 

Rearm mode

 

Auto

 

 

 

Hysteresis support

 

No

 

 

 

Threshold access support

 

Readable/Settable

 

 

 

Event message control

 

Entire Sensor only

 

 

 

Readable threshold mask,

 

 

 

 

 

Settable threshold mask (bytes

0x10, 0x10

Upper Critical Threshold is

19, 20)

 

Readable and Settable

 

 

 

Reading Type

 

Unsigned

 

 

 

Upper critical threshold

0xFF

2.499 Volts

 

 

 

2.3.5.2Temperature Sensors

The following tables describe the analog temperature sensors available on the physical SAM.

Table 2-8 Sensor No. 6 MAX6656 INT@1A

 

Feature

 

Raw Value/Description

Interpreted Value

 

 

 

 

 

 

 

 

Sensor Name

 

MAX6656 INT @1A

 

 

 

 

 

 

 

 

 

Device

 

 

 

 

 

 

 

 

 

 

 

Sensor Type

 

0x01

Temperature

 

 

 

 

 

 

 

 

Class

 

0x01

Threshold

 

 

 

 

 

 

 

 

 

 

 

 

 

32

 

AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)

Page 32
Image 32