AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)
FRU Information and Sensor Data Records Power Entry Module Analog Sensors
128
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F, 0x3F Upper and Lower Non-Critical,
Critical and Non-Recoverable
Thresholds are Readable and
Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0x87, 0x7D, 0x74 (7.02, 6.5, 6.032) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xAE, 0xB7, 0xC1 (0.048, 9.516, 10.036) Volts
Table 2-137 Sensor No. 4 +12 V Backplane
Feature Raw Value/Description Interpreted Value
Sensor Name +12 V Backplane
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3F, 0x3F Upper and Lower Non-Critical,
Critical and Non-Recoverable
Thresholds are Readable and
Settable
Reading Type Unsigned
Lower Non-Critical, Critical and
Non-Recoverable thresholds
0xD4, 0xCA, 0xC1 (11.024, 10.504, 10.036) Volts
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xFA, 0xFF, 0xFF (13, 13.26, 13.26) Volts
Table 2-138 Sensor No. 11 +48.0 V Feed
Feature Raw Value/Description Interpreted Value
Sensor Name +48.0 V FEED
Device
Sensor Type 0x02 Voltage
Class 0x01 Threshold
Table 2-136 Sensor No. 3 +8 V (continued)
Feature Raw Value/Description Interpreted Value