FRU Information and Sensor Data Records

E-Keying

 

 

2.3.2E-Keying

The physical SAMs (IPMB 0xfc and 0xfe) each contain the following Point-to-Point Connectivity Record:

PICMG

Board Point-to-Point Connectivity Record (ID=0x14)

Version = 0

 

 

OEM GUID

Count

= 0

 

Link Descriptor:

 

 

Link

Grouping ID

= 0x00

 

Link

Type

= 0x01

PICMG®3.0 Base 10/100/1000 Base-T

Link

Type Extension

= 0x0 10/100/1000BASE-T Link (four-pair)

Link

Designator

= 0x101 Channel1/BaseInterface/Ports0

Link Descriptor:

 

 

Link

Grouping ID

= 0x00

 

Link

Type

= 0x01

PICMG®3.0 Base 10/100/1000 Base-T

Link

Type Extension

= 0x0 10/100/1000BASE-T Link (four-pair)

Link

Designator

= 0x102 Channel2/BaseInterface/Ports0

2.3.3Power Configuration

The following table describes the power configuration for the Physical SAM.

Table 2-2 SAM Physical Power Configuration

Item

Value

Meaning

 

 

 

Dynamic power reconfiguration

No

Possibility to change FRU power consumption without

support

 

switching it off, according to ATCA

 

 

 

Dynamic power configuration

No

Are the Power Draw levels fixed or these may vary if

 

 

additional components are hot inserted or onboard

 

 

components power consumption is changing

 

 

dynamically

 

 

 

Number of Power Draw Levels

1

The amount of possible power levels, normally 1

 

 

 

Early Power Draw Levels, Watt

20

Complete early power consumption including IPMC

 

 

 

Steady state Power Draw Levels,

20

Complete steady power consumption including IPMC

Watt

 

 

 

 

 

Transition from Early to Steady

0

How long does board consumes early power. Early

levels, sec

 

power is normally bigger than steady

 

 

 

28

AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)

Page 28
Image 28
Emerson AXP1406, AXP1600 manual Keying, SAM Physical Power Configuration