Supported IPMI Commands

Emerson and Pigeon Point OEM Commands

 

 

1.4Emerson and Pigeon Point OEM Commands

These commands can only be sent to the Emerson AXP1406 and AXP1600 Shelf Managers, sending these commands to other shelf managers or IPMCs will result in error responses or undefined behavior.

The SAM supports these OEM IPMI commands that are not defined in the IPMI 1.5 or PICMG 3.0 specifications.

Table 1-14 OEM Command Summary

IPMI NetFn (Request/Response)

Emerson OEM Command

IPMI Cmd

 

 

 

Get Shelf Configuration Record

0x2E / 0x2F

0x01

 

 

 

Shelf Manager Switchover

0x2E / 0x2F

0x02

 

 

 

Set FRU Extracted

0x2E / 0x2F

0x03

 

 

 

This command gets the shelf configuration for the AXP1600.

Table 1-15 Get Shelf Configuration Record (Cmd = 0x01)

 

Byte

Data field

 

 

 

Request data

1

Pigeon Point Systems IANA Enterprise number, LSB first

 

 

 

 

2

0x0A

 

 

 

 

3

0x40

 

 

0x00

 

 

 

 

4

IANA enterprise number for the desired record, LSB first

 

 

 

 

5

 

 

 

 

 

6

 

 

 

 

 

7

Record Type

 

 

 

 

8

Record Number

 

 

 

 

9

Offset within record

 

 

 

 

10

Count of bytes to retrieve

 

 

 

Response

1

Completion Code

data

 

 

 

 

 

 

2

Pigeon Point Systems IANA Enterprise number, LSB first

 

 

0x0A

 

3

 

 

 

 

0x40

 

4

 

 

 

 

 

 

5

Requested bytes from the specified Shelf FRU record

 

 

 

 

 

 

 

 

 

n

 

 

 

 

22

AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)

Page 22
Image 22
Emerson AXP1406, AXP1600 Emerson and Pigeon Point OEM Commands, OEM Command Summary, Get Shelf Configuration Record Cmd =