Shelf FRU Info (Emerson OEM)

OEM Sensors

 

 

Bit 5 (CRC)

Bit 6 (Watchdog)

Bit 7 (RTC)

3.1.4Shelf FRU Info (Emerson OEM)

This sensor reports the validity of the Shelf FRU Information. This sensor is available on each physical ShMM controller. The check it performs is basic checksum and length checks based on information of previous sections of the FRU area; and key bytes that are expected to have certain values.

zSensor Reading - 0x00 (meaningless since discrete sensor reading)

zCurrent State Mask - 0x01 Shelf FRU Info not found (Disabled) 0x02 Shelf FRU Info found (Enabled)

zEvents - Events are generated when the state of the FRU Info found state changes.

Event Data Byte 1 = 0x01 Shelf FRU Info not found (Disabled) 0x02 Shelf FRU Info found (Enabled)

Event Data Byte 2 = 0xFF (Unspecified)

Event Data Byte 3 = 0xFF (Unspecified)

3.1.5FT -48 V Fuse (Emerson OEM)

This sensor reads the System Status Register of the respective Fan Tray and verifies if the bit for 48 V input power OK is set. The 48 V input power ok bit is set if all input fuses are intact.

zSensor Reading - 0x00 (NULL Discrete sensor reading)

zCurrent State Mask - 0x01 (State Deasserted, all input fuses are intact) 0x02 (State Asserted, not all input fuses are intact)

zEvents - No events are generated by this sensor.

AXP1406/AXP1600 Subsystem IPMI Programmer’s Reference (6806800B66C)

139

Page 139
Image 139
Emerson AXP1600, AXP1406 manual Shelf FRU Info Emerson OEM, FT -48 V Fuse Emerson OEM