E-9

TROUbLESHOOTING

E-9

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION

 

ARCLINK SYSTEM ERROR CODES

 

 

 

 

 

 

Err 33

Capacitor bank "B" under

1. The power source input power

 

 

voltage.

 

may be wired incorrectly. Verify

 

 

 

 

the power source reconnect panel

 

 

 

 

wiring matches the input power.

 

 

 

2.

See the power source service

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

1.

The power source input power

 

Err 34

Capacitor bank "A" overvolt-

 

may be wired incorrectly. Verify

 

 

age.

 

the power source reconnect panel

 

 

 

 

wiring matches the input power.

 

 

 

2.

See the power source service

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

1.

The power source input power

 

 

 

 

may be wired incorrectly. Verify

 

Err 35

Capacitor bank "B" overvolt-

 

the power source reconnect panel

 

 

age.

 

wiring matches the input power.

 

 

 

2.

See the power source service

If all recommended possible areas of

 

 

 

Manual.

misadjustment have been checked

 

 

 

 

 

and the problem persists, Contact

 

 

 

 

 

 

 

1.

The power source has exceeded

your local Lincoln Authorized

 

 

 

the output current limits. Adjust

Field Service Facility.

 

 

 

the welding procedure to reduce

 

Err 41

Long term secondary over-

 

the current draw. The welding

 

 

current.

 

procedure may exceed the capac-

 

 

 

 

ity of the power source.

 

 

 

2.

See the power source service

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

1.

Verify the power source reconnect

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

Err 43

Capacitors are out of bal-

 

 

 

 

 

ance

2.

See the power source service

 

 

 

 

Manual.

 

 

 

A high level of output current (long

 

 

 

average ) has caused an overload.

 

 

 

 

 

 

This happens when the wrong

Err 54

Short term secondary over-

 

 

 

Output stud is used on an STT

 

 

 

machine or if there is a missing input

 

current.

 

 

 

 

 

 

 

phase. When this fault occurs, the

 

 

 

 

 

 

 

 

 

 

machine output will be shut off.

 

 

 

 

 

 

CAUTION