TROUbLESHOOTING | ||
|
|
|
Observe all Safety Guidelines detailed throughout this manual
Error Codes for the Power Wave® 455: Code 10675 and above.
ERROR CODES FOR THE POWER WAVE® 455
The following is a list of possible error codes that the Power Feed™ 10M Dual Wire Feeder can output via the dis- play on this user interface.
Note: For any Err # listed below write down the error number for reference and try cycling power to see if the error clears itself. If not, refer to the What to Do column for the given Err.
PRObLEMS | POSSIbLE | RECOMMENDED |
(SYMPTOMS) | CAUSE | COURSE OF ACTION |
|
|
|
Display shows any of the following: |
|
|
|
|
|
Err 49 | Single phase error | Indicates machine is running on sin- |
|
| gle phase input power. Usually |
|
| caused by the loss of the middle leg |
|
| (L2). |
|
|
|
Other |
| Error codes that contain three or four |
|
| digits are defined as fatal errors. |
|
| These codes generally indicate inter- |
|
| nal errors on the Power Source |
|
| Control Board. If cycling the input |
|
| power on the machine does not clear |
|
| the error, try reloading the operating |
|
| system. If this fails, replace the con- |
|
| trol board. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.