Error Codes for the Power Wave 455: Code 10675 and above.
ERROR CODES FOR THE POWER WAVE 455
The following is a list of possible error codes that the Power Feed 10M Dual Wire Feeder can output via the dis- play on this user interface.
Note: For any Err # listed below write down the error number for reference and try cycling power to see if the error clears itself. If not, refer to the What to Do column for the given Err.
| PRObLEMS | POSSIbLE | RECOMMENDED | |
| (SYMPTOMS) | CAUSE | COURSE OF ACTION | |
|
|
|
|
|
| Display shows any of the following: |
|
|
|
|
|
|
|
|
| Err 11 | CAN communication bus off. | Probably due to excessive number | |
|
|
| of communication errors. | |
|
|
|
|
|
| Err 12 | User Interface time out error. | User Interface is no longer respond- | |
|
|
| ing to the Power Source. The most | |
|
|
| likely cause is a fault/bad connection | |
|
|
| in the communication leads or con- | |
|
|
| trol cable. | |
|
|
|
|
|
| Err 21 | Unprogrammed Weld Mode. | Contact the Service Department for | |
|
|
| instructions on reloading the | |
|
|
| Welding Software. | |
|
|
|
| |
| Err 22 | Empty Weld Table. | Contact the Service Department for | |
|
|
| instructions on reloading the | |
|
|
| Welding Software. | |
|
|
|
|
|
| Err 23 | Weld Table checksum error. | Contact the Service Department for | |
|
|
| instructions on reloading the | |
|
|
| Welding Software. | |
|
|
|
| |
| Err 31 | Primary overcurrent error. | Excessive Primary current present. | |
|
|
| May be related to a switch board or | |
|
|
| output rectifier failure. | |
|
|
|
| |
| Err 32 | Capacitor "A" under voltage | Low voltage on the main capacitors. | |
|
| (Left side facing machine) | May be caused by improper input | |
|
|
| configuration. | |
|
|
| When accompanied by an overvolt- | |
|
|
| age error on the same side, it indi- | |
|
|
| cates no capacitor voltage present | |
|
|
| on that side, and is usually the result | |
| Err 33 | Capacitor "B" under voltage | of an open or short in the primary | |
|
| (Right side facing machine) | side of the machine. | |
|
|
|
|
|
|
|
|
|
|
CAUTION