Image 58

E-2

TROUbLESHOOTING

E-2

 

 

 

Observe all Safety Guidelines detailed throughout this manual Error Codes for the Power Wave 455: Code 10555 and below

Note: For any Err # listed below write down the error number for refference and try cycling power to see if the error clears itself. If not, refer to what the What to Do column for the given Err.

 

PRObLEMS

 

POSSIbLE

 

 

RECOMMENDED

 

(SYMPTOMS)

 

CAUSE

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

Display shows any of the following:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Err 001

 

 

More than 1 CB with the same

 

 

Make sure the group dip switch set-

 

 

 

 

 

 

group number.

 

 

ting is unique for each CB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Err 003

 

 

Too many objects in group.

 

 

A given group can only support up

 

 

 

 

 

 

 

 

 

to 7 objects. Remove any objects

 

 

 

 

 

 

 

 

 

over 7 from the group either by

 

 

 

 

 

 

 

 

 

changing the group dip switch set-

 

 

 

 

 

 

 

 

 

tings or physically disconnecting any

 

 

 

 

 

 

 

 

 

objects over 7 in the group.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Err 004

 

More than 1 object of the same

 

 

Adjust the dip switch setting to make

 

 

 

 

eqipment type with the same group

 

 

either the group # or feed head #

 

 

 

 

# and feed head #.

 

 

unique for all oobjects of the same

 

 

 

 

 

 

 

 

equipment type.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Err 005

 

 

A feed head has its feed head dip

 

 

The appropriate feed head # is 1

 

 

 

 

 

switches set to zero in a group with

 

 

through 7. Check the dip switch set-

 

 

 

 

 

more than one object.

 

 

ting chart in INSTALLATION section

 

 

 

 

 

 

 

 

 

and set the switches to make the

 

 

 

 

 

 

 

 

 

Feed head ID non-zero.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Err 006

Did not receive a recognition com-

Check to see if the status light is not

 

 

 

 

mand from the power source.

solid green on the power source

 

 

 

 

 

 

 

 

(refer to status light states in OPER-

 

 

 

 

 

 

 

 

ATION section if not). Also, check

 

 

 

 

 

 

 

 

continuity in the communication lines

 

 

 

 

 

 

 

 

from CB to Power Source (refer to

 

 

 

 

 

 

 

 

wiring diagram). Refer to Power

 

 

 

 

 

 

 

 

source trouble shooting section for

 

 

 

 

 

 

 

 

additional information. If all these

 

 

 

 

 

 

 

 

avenues fail, replace CB mother PC

 

 

 

 

 

 

 

 

board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER FEED™ 10M SINGLE WIRE FEEDER

Page 58
Image 58
Lincoln Electric IM827-D manual PRObLEMS POSSIbLE, Recommended, Symptoms Cause Course of Action, Err