Lincoln Electric IM827-D manual User Defined Parameters

Models: IM827-D

1 75
Download 75 pages 15.54 Kb
Page 34
Image 34

b-11

 

OPERATION

b-11

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

Exit Setup Menu

 

 

 

P.0

This setup menu parameter can be used to exit the setup menu. When P.0 is displayed, press

 

 

 

 

the left Mode Select button to exit the setup menu.

 

 

 

 

 

 

 

 

P.1

Wire Feed Speed Units

 

 

 

 

 

P.1 selects which units wire feed speed will be displayed in. English = in/minute wire feed speed

 

 

 

 

units (default). Metric = m/minute wire feed speed units.

 

 

 

 

 

 

 

 

P.2

Arc Display Mode

 

 

 

 

 

P.2 selects what value will be shown on the upper left display while welding. Amps = The left

 

 

 

 

display shows Amperage while welding (default). WFS = The left display shows Wire Feed

 

 

 

 

Speed while welding.

 

 

 

 

 

 

 

 

P.3

Display Energy

 

 

 

 

 

P.3 selects whether or not energy is displayed on the MSP4 while welding. The total energy

 

 

 

 

from the previous weld will persist on the MSP4 display until another weld is started, or a user

 

 

 

 

interface control is changed. P.3 will only show up in the list if the power source is capable of

 

 

 

 

calculating energy (a power source software update may be necessary). When P.3 = No, ener-

 

 

 

 

gy will not be displayed (default). When P.3 = Yes, energy is displayed.

 

 

 

 

 

 

 

 

P.4

Recall Memory with Trigger

 

 

 

 

 

Allows the operator to recall a memory by quickly pulling and releasing the gun trigger. To recall

 

 

 

 

a memory, quickly pull and release the trigger the number of times that correspond to the mem-

 

 

 

 

ory number. For example, to recall memory 3, quickly pull and release the trigger 3 times. To

 

 

 

 

recall memory 1, quickly pull and release the trigger the number of user memories plus 1.

 

 

 

 

Memories cannot be recalled while the system is welding. A memory panel must be installed in

 

 

 

 

order to use this feature.

 

 

 

 

 

Disabled = The gun trigger cannot be used to recall user memories (default).

 

 

 

 

 

Enabled = The gun trigger can be used to recall user memories.

 

 

 

 

 

 

 

POWER FEED™ 10M SINGLE WIRE FEEDER

Page 34